S T 1 9 1 7 1 W D B A R R A C U D A 9 SEAGATE Native| Translation ------+-----+-----+----- Form 3.5"/HH Cylinders 5333| | | Capacity form/unform 9100/11700 MB Heads | | | Seek time / track 9.0/ 1.0 ms Sector/track | | | Controller SCSI3 DI/WI/ULTRA Precompensation Cache/Buffer 512 KB MULTI-SEGMEN Landing Zone Data transfer rate 8.500 MB/S int Bytes/Sector 512 20.000 MB/S ext Recording method PRML 0/4/4 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 50 | -40 70 Power: sleep W Humidity % | standby W Altitude km | idle 12.4 W Shock g | seek W Rotation RPM 7200 read/write W Acoustic dBA spin-up W ECC Bit MTBF h 1000000 Warranty Month 60 Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** SEAGATE ST19171W/WD INSTALLATION GUIDE 83329020 REV. A 2/96 +---------------------------------------+----------1------+ 1-+ +----------+J2 |XX | |J6 |XXI | | |XXN | | |XXT +-+ W MODELS |XXE | |XXR | |XXF | |XXA | |XXC | 1XXE | |12+ | || | J1 | || | | |+-1 | |XX Power | |XX +---------------------------------------------------------+ 1 ********************************************************************** J U M P E R S ********************************************************************** SEAGATE ST19171W/WD INSTALLATION GUIDE 83329020 REV. A 2/96 Jumper Setting ============== J6 Setting the SCSI ID jumpers ------------------------------ Use the J6 connector to set the SCSI ID. To change the SCSI ID, install jumpers on the appropriate pins as shown. Optional connections to switching circuits in host equipment are provided on J1 auxiliary to set the SCSI ID. | ---+--------+----------------+-+ | * * * *|. . . . * * * 1 | | * * * *|. . . . * * * * |J6 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * * * 1 | | * * * *|* * * * * * * * |J6 SCSI ID 0 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * * * X | | * * * *|* * * * * * * X |J6 SCSI ID 1 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * * X 1 | | * * * *|* * * * * * X * |J6 SCSI ID 2 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * * X X | | * * * *|* * * * * * X X |J6 SCSI ID 3 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * X * 1 | | * * * *|* * * * * X * * |J6 SCSI ID 4 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * X * X | | * * * *|* * * * * X * X |J6 SCSI ID 5 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * X X 1 | | * * * *|* * * * * X X * |J6 SCSI ID 6 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * * X X X | | * * * *|* * * * * X X X |J6 SCSI ID 7 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X * * 1 | | * * * *|* * * * X * * * |J6 SCSI ID 8 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X * * X | | * * * *|* * * * X * * X |J6 SCSI ID 9 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X * X 1 | | * * * *|* * * * X * X * |J6 SCSI ID 10 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X * X X | | * * * *|* * * * X * X X |J6 SCSI ID 11 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X X * 1 | | * * * *|* * * * X X * * |J6 SCSI ID 12 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X X * X | | * * * *|* * * * X X * X |J6 SCSI ID 13 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X X X 1 | | * * * *|* * * * X X X * |J6 SCSI ID 14 +--------+----------------+ ---+RESERVED+----------------+ | * * * *|* * * * X X X X | | * * * *|* * * * X X X X |J6 SCSI ID 15 +--------+----------------+ +--- SCSI ID A3 | +- SCSI ID A2 | | +SCSI ID A1 --68PIN-----+-----J1-+-+---+-------+ * * * * 1|* * * * * * 1 |POWER | * * * * |12* * * * * * |X X X X| ----------+------------+-+-------1 +SCSI ID A0 J1 Pin 2 = Fault LED J1 Pin 4 = Vendor Unique J1 Pin 6 = Spindle Sync J1 Pin 8 = Activity LED J1 Pin 9+12 = No Connection J1 Pin 10 = Ground J1 Pin 11 = +5V Pins 2, 4, 6, and 8 are driven low for 250ms after PWR ON and reset to allow jumper selectable SCSI ID. J2 Terminating the drive ------------------------ ST19171W drives are terminated with permanently mounted IC active terminators. If you install one of these drives and it is not on the end of the SCSI bus, disable the terminators by removing the jumper from pins 15 and 16 of connector J2. If you install the drive on the end of the SCSI bus, enable termination by installing a jumper on pins 15 and 16 of connector J2. +---------------+ --+* * * * * * * 1+-- J2 * * * * * * * * T D M W P E T T E S E P D S P P +---------------+ --+X . . . . . . 1+-- J2 Enable SCSI terminator (default) X . . . . . . . ST19171W only +---------------+ --+* . . . . . . 1+-- J2 Disable SCSI terminator * . . . . . . . NOTE Use active (ANSI SCSI-2 Alternative 2) terminators when terminating the bus. ST19171WD drives do not have internal terminators or any other way of adding internal termination to the drive. You must provide external differential termination to these drives when termination is required. Terminator Power ---------------- There are three posiible terminator power configurations for ST19171W drives. You will not normally need to change this option and can leave the drive configured as it was shipped from the factory. ST19171W +---------------+ --+. . . . . . X 1+-- J2 Terminator Power from Drive (DEFAULT) . . . . . . X * +---------------+ --+. . . . . . * X+-- J2 Terminator Power to SCSI Bus . . . . . . * X +---------------+ --+. . . . . . * 1+-- J2 Terminator Power from SCSI BUS . . . . . . xxx ST19171WD +---------------+ --+. . . . . . * X+-- J2 Terminator Power to SCSI Bus (DEFAULT) . . . . . . * X +---------------+ --+. . . . . . * *+-- J2 Host adapter or other device provides . . . . . . * * terminator power to external terminator. Other applicable jumper options ------------------------------- +---------------+ --+. . . . . * . 1+-- J2 RESERVED . . . . . * . . Delay Motor Start option ------------------------ Delay Motor Start option (valid only if the Enable Motor Start jumper is not connected) +---------------+ --+. * . . . . . 1+-- J2 Disable the Delay Motor Start option . * . . . . . . (default) +---------------+ --+. X . . . . . 1+-- J2 Motor start delay equal to the SCSI ID . X . . . . . . multiplied by 12 seconds. For example, if the SCSI ID = 2, the drive starts in 24 seconds. Motor Start option ------------------ +---------------+ --+. . * . . . . 1+-- J2 Disable motor start (default). The drive . . * . . . . . starts according to the Delay Motor Start Option. +---------------+ --+. . X . . . . 1+-- J2 Enable motor start. The drive waits for the . . X . . . . . Start Unit command from the host before starting the spindle motor. Write Protect Option -------------------- +---------------+ --+. . . * . . . 1+-- J2 Write protect = Off (enables writing - . . . * . . . . default) +---------------+ --+. . . X . . . 1+-- J2 Write protect = ON (disables writing) . . . X . . . . Parity Check Option ------------------- +---------------+ --+. . . . * . . 1+-- J2 Enables parity check of SCSI bus (default) . . . . * . . . +---------------+ --+. . . . X . . 1+-- J2 Disables parity check . . . . X . . . J6 Jumper Options ----------------- | ---+--------+----------------+-+ | * * * *|. * * . . . . 1 | | * * * *|. * * . . . . . |J6 RESERVED +RESERVED+----------------+ | ---+--------+----------------+-+ | * * * *|* . . . . . . 1 | | * * * *|* . . . . . . . |J6 Remote LED +RESERVED+----------------+ REAR VIEW (ST-19171W only) (TOP) Auxiliary ------------------- +-----1++---------+ ---( +++++++++++++++++1)-+::::::++ O O O O +--- \------------|----/ +------++-5-G-G-12+ 68 pin I/O Cable+ |||||| V V Connection Male |||||| |||||| |||||| Auxiliary option header |||||| pin-11 +5V ---------+||||| pin-10 GND ----------+|||| SCSI ID = 8 -----------+||| SCSI ID = 4 ------------+|| or pin-6 REFIND+ ------+|| SCSI ID = 2 -------------+| SCSI ID = 1 --------------+ SCSI ID = 0 (none) REAR VIEW (ST-19171WC only) 80 pin I/O and DC Power Wall/bracket Connection | Female J1 /----|---------------\ TOP (HDA) -----------/ ++++++++++++++++++++ \------------ (--1------------------40-) BOTTOM Notes on 80 pin I/O connector: pins 1 - 4 = +12V 41 - 44 = 12V GND 34 - 36 = +5V 74 - 76 = 5V GND 37 = SYNC 77 = LEDC 38 = MTRON 78 = DLYDST 39 = SCSIA0 79 = SCSIA1 40 = SCSIA2 80 = SCSIA3 Mating NC connector: AMP US p/n: 2-557103-1 straight-in, Male 80-pin 2-557101-1 right angle to PCB SIDE VIEW (ST-19171W/WC) BACK +-+ J2 12345678 TOP (HDA) FRONT OF J1+------------------------------------------------- OF DRIVE +-+ :::::::: BOTTOM DRIVE |||||||| |Terminator Power +||||||+ Enable T-Res (not used on WC,WD models) ++Terminator Power -+||||+- Start Delay (12 secs * ID) | Reserved --+||+-- Motor Start | Parity Disable ---++--- Write Protect | | | +--------------------------------+ +-+ Termination Power-source Table | +--------------------------------+-------------------------+ |xxxxx....xxxxx....xxxxxPWAxedgexxxxx | | A Drive Supplies Bus | | 1 2 1 2 1 2 1 2 B Drive Supplies Own | | C Bus Supplies Drive | | X * * X * * xxx D Differential only: | | x * * x xxx * * Drive Supplies Bus | | A B C D | +---------Default------------------------------------------+ (not used on WC model) Note: WD drives do not have internal terminators or any other way of adding internal terminators to the drive; use external active termination if required. FRONT VIEW (ST-19171W/WC) +--+Reserved. Shipped with cover installed. | +Do not remove. Do not install jumpers TOP (HDA) ++---+-----1+ --------PWA-------------+::::|::::::+--- x BOTTOM +----+123456+ | J6 |||||| LED -+ |||||| Remote LED +||||+ ID 1 (pin-11 +5V) |||+- ID 2 RESERVED -+|+-- ID 4 +--- ID 8 ********************************************************************** G E N E R A L ********************************************************************** SEAGATE SUPPORT SERVICES Seagate Technology ------------------ Technical Support Services If you need assistance installing your drive, consult your dealer. Dealers are familiar with their unique system configurations and can help you with system conflicts and other technical issues. If you need additional assistance with your Seagate(r) drive or other Seagate products, use one of the Seagate technical support services listed below. SeaFONE at 1-800-SEAGATE (1-800-732-4283) Seagate's 800 number allows toll-free access to automated self-help services, providing answers to commonly asked questions, troubleshooting tips and specifications for disc drives and tape drives. This service is available 24 hours daily and requires a touch-tone phone. If you need to speak to a technical support engineer, dial this number and listen to the options for technical support. (International callers can also reach this automated self-help service by dialing 408-456-4496). Seagate Technology online services Using a modem, you can obtain troubleshooting tips, free utility programs, drive specifications and jumper settings for Seagate's entire product line. You can also download software for installing and analyzing your drive. SeaNET You can obtain technical information on Seagate drives, Seagate software and much more over the Internet from Seagate's World Wide Web home page (http://www.seagate.com) or Seagate's ftp server (ftp://ftp.seagate.com). You may also send E-mail with your questions to DiscSupport@ Seagate.com or TapeSupport@Seagate.com. SeaBOARD SeaBOARD is a computer bulletin board system (BBS) that contains information about Seagate's disc and tape drive products and is available 24 hours daily. Set your communications software to eight data bits, no parity and one stop bit (8-N-1). SeaBOARD phone numbers are listed in the following table. BBS Location Modem number United States Disc: 408-434-1080; Tape: 408-456-4415 England 44-1628-478011 France 33 1-48 25 35 95 Germany 49-89-140-9331 Singapore 65-292-6973 Thailand 662-531-8111 Australia 61-2-9756-2359 Taiwan 886-2-719-6075 Seagate CompuServe forum Online technical support for Seagate products is available on CompuServe. To access our technical support forum, type go seagate. This forum provides information similar to that found on SeaBOARD. In addition, you can type questions or browse through previous questions and answers on the forum messages. Seagate Technology FAX services SeaFAX You can use a touch-tone telephone to access Seagate's automated FAX system to receive technical support information by return FAX. This service is available 24 hours daily. Location Telephone number United States 1-800-SEAGATE or 408-456-4496 England 44-1628-894084 Australia 61-2-9756-5170 Seagate technical support FAX You can FAX questions or comments to technical support specialists 24 hours daily. Responses are sent during business hours. Location FAX number United States 408-944-9120 England 44-1628-890660 France 33 1-46 04 42 50 Germany 49-89-1430-5100 Australia 61-2-9725-4052 Singapore 65-293-4722 Hong Kong 852-2368 7173 Taiwan 886-2-715-2923 Korea 82-2-556-7294/4251 Seagate technical support You can talk to a technical support specialist during business hours Monday through Friday for one-on-one technical help. Before calling, note your system configuration and drive model number (STxxxx). There are several technical support phone numbers available for various Seagate products. Location Telephone number United States Please dial 1-800-SEAGATE for the specific product telephone number. (6:00 A.M. to 11:15 A.M., 12:30 P.M. to 5:00 P.M., Pacific time, M-F) England 44-1628-894083 (10:00 A.M. to 1:00 P.M., 2:00 P.M. to 5:00 P.M., M-F) France 33 1-41 86 10 86 (9:30 A.M. to 12:30 P.M., 2:00 P.M. to 5:00 P.M., M-F) Germany Disc: 49-89-140-9332; (9:30 A.M. to 12:30 P.M., 2:00 P.M. to 4:00 P.M., M-F) Tape: 49-89-140-9333 Australia 61-2-9725-3366 (9:00 A.M. to 5:00 P.M., M-F) Singapore 65-290-3998 (9:00 A.M. to 12:00 P.M., 2:00 P.M. to 5:00 P.M., M-F) Hong Kong 852-2368 9918 Taiwan 886-2-514-2237 Korea 82-2-556-8241 SeaTDD 408-944-9121 Using a telecommunications device for the deaf (TDD), you can send questions or comments 24 hours daily and exchange messages with a technical support specialist between 6:00 A.M. to 11:15 A.M. and 12:30 P.M. to 5:00 P.M. (Pacific time) Monday through Friday. Customer Service Centers Seagate direct OEM, Distribution, System Integrator and Retail customers should contact your Seagate Service Representative for warranty information. Other customers contact your place of purchase. Seagate offers comprehensive customer support for all Seagate drives. Seagate customer service centers are the only facilities authorized to service Seagate drives. These services are available worldwide. Location Telephone number FAX number United States 1-800-468-3472; 405-949-6740 Other Americas (Canada & Brazil) 405-949-6706; 405-949-6738 Mexico 525-546-6965; 525-546-4888 Europe, Middle East & Africa 31-2065-43300; 31-2065-34320 Asia Pacific & Australia 65-485-3595; 65-485-4980 Japan 81-3-5462-2904; 81-3-3462-2979 Seagate, Seagate Technology and the Seagate logo are registered trademarks of Seagate Technology, Inc. SeaFAX, SeaFONE, SeaBOARD, SeaTDD, SeaNET, Medalist and DiscWizard are either trademarks or registered trademarks of Seagate Technology, Inc. or one of its subsidiaries. All other trademarks or registered trademarks are the property of their respective owners.