0 6 6 1 - 3 7 1 IBM NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/HH Cylinders 949| | | Capacity form/unform 320/ 371 MB Heads 15| | | Seek time / track 12.5/ 4.0 ms Sector/track | | | Controller SCSI2 SINGLE-ENDED Precompensation Cache/Buffer 64 KB DUAL-PORTED Landing Zone Data transfer rate 2.000 MB/S int Bytes/Sector 512 4.000 MB/S ext SYNC Recording method RLL 1/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 10 50 | -40 60 Power: sleep W Humidity % 8 80 | 5 99 standby W Altitude km -0.305 3.048| -0.305 9.144 idle 11.9 W Shock g 10 | 35 seek W Rotation RPM 4316 read/write W Acoustic dBA spin-up W ECC Bit 48 MTBF h 150000 Warranty Month Lift/Lock/Park YES Certificates CSA,FCC,IEC380,IEC435,UL19... ********************************************************************** L A Y O U T ********************************************************************** IBM 0661-371 PRODUCT DESCRIPTION VER. 0.7, FEBRUARY 18, 1991 +-------------------------------------------------------------+ |+-------------------SCSI--------------------------+ +Power--+| ||o o o o o o o o o o o o o o o o o o o o o o o o 1| |1 O O O|| ||o o o o o o o o o o o o o o o o o o o o o o o o o| | || |+-------------------------------------------------+ +-------+| | +---------+ +----+ | |+-+o o o o| | |Vent Hole | || |o o o o o| +----+ | || +---------+ +----+ | ||Option Jumper | |Vent Hole | ||Block +----+ | || | |+Bit 0 +----+ | | | |Vent Hole | | +----+ | +-------------------------------------------------------------+ ********************************************************************** J U M P E R S ********************************************************************** IBM 0661-371 PRODUCT DESCRIPTION VER. 0.7, FEBRUARY 18, 1991 Jumper Setting ============== Option Jumper Block ------------------- The jumper block is used to select the SCSI device ID and to control spindle motor start. All signal option lines can be driven from one ground line but the ground pins should only be used for driving option lines. +------- C3; Bit2 (MSB) C2; Bit1 -------+ | +----- Blank Polarity C1; Bit0 (LSB) -----+ | | | +--- D2; Remote Start ++-+-+-+-++ |o o o o| |o o o o o| ++-+-+-+-++ Ground A1 -----+ | | | +--- B2; Ground Ground A2 -------+ | +----- B1; * +------- A3; Ground * If pin B1 is high on power up, (high is floating), the B1 pin will be used as an output for Motor Active, (high=motor off, low=motor on); and if pin B1 is low on power up, pin B1 stays as an input. NOTE If the remote start shunt is not on, the file starts by SCSI command only. SCSI Address Selection ---------------------- +----------+-----------------------+ | ADDRESS | Jumpers | | | Bit 2 | Bit 1 | Bit 0 | +----------+-------+-------+-------+ | 0 | OPEN | OPEN | OPEN | +----------+-------+-------+-------+ | 1 | OPEN | OPEN | CLOSED| +----------+-------+-------+-------+ | 2 | OPEN | CLOSED| OPEN | +----------+-------+-------+-------+ | 3 | OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+ | 4 | CLOSED| OPEN | OPEN | +----------+-------+-------+-------+ | 5 | CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+ | 6 | CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+ | 7 | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+ ********************************************************************** I N S T A L L ********************************************************************** IBM 0661-371 PRODUCT DESCRIPTION VER. 0.7, FEBRUARY 18, 1991 Notes on Installation ===================== Mounting -------- The drive can be mounted in the following posistions listed below. - Bottom Side Down - Right Side Down - Left Side Down - Rear Side Down Four mounting holes are provided on the bottom of the drive, and two mounting holes are provided on each side of the drive. The torque applied to the mounting screws is not exceed 1.0 Newton- meters 0.1 Newton-meters. Clearances ---------- A minimum of 2 mm clearance MUST be given to the bottom surface except at the bottom mounting holes. For proper cooling it is suggested that a clearance of 6 mm be provided under the file and on top of the file. Precaution must be taken so as not to block any of the vent holes on the side and ends of the file. NOTE The top of the drive will not exceed the height dimension by more than 2 millimeters during a 35 G 20 millisecond drop. Power Connector --------------- +------------+ pin 1 +12 V | 1 2 3 4 | pin 2 GND +------------+ pin 3 GND pin 4 + 5 V The DC power connector is designed to mate with AMP part 1-480424-0 using AMP pins part 350078-4 (strip) or part 61173-4 (loose piece), or their equivalent. SCSI Signal Connector --------------------- The SCSI signal connector is a 50-pin connector Molex part #70246 meeting ANSI/SCSI specifications. SCSI Bus Terminators -------------------- The file has no internal SCSI bus terminators. The user is responsible for properly terminating and powering the SCSI bus in the using system. AMP #88-4163-081-1 or DATA MATE DM500-06-8 or equivalent external terminator may be used for termination of the file. For a single-ended cable a 50 conductor flat cable or a 25 signal twisted cable can be used with a maximum length of 6.0 meters, and a stub length not to exceed 0.1 meters. This file has an internal stub length of 0.077 meters. To remain compliant with ANSI, the SCSI bus cable must not add more than 0.023 meters additional stub length. Actuator -------- The read/write heads are mounted on the actuator. The actuator is a swing-arm assembly driven by a voice coil motor. A closed-loop positioning servo controls the movement of the actuator. A dedicated servo surface and head supplies feedback to the positioning servo to keep the read/write heads centered over the desired track. During seeks, the servo head provides track crossing information to the servo. The actuator assembly is balanced to allow vertical or horizontal mounting without adjustment. When the unit is stopped (via a SCSI command or power off condition) the actuator automatically moves the heads to a dedicated landing zone outside of the data area, where the actuator is locked. ********************************************************************** F E A T U R E S ********************************************************************** IBM 0661-371 PRODUCT DESCRIPTION VER. 0.7, FEBRUARY 18, 1991 Description/Features -------------------- i.e. - Industry-standard interface: ANSI/SCSI-2 - Thermal compensation - Integrated controller - Logical block addressing - Implied seeks - SCSI disconnect and reconnect capability - SCSI bus parity - Rotary voice coil motor actuator - Closed-loop actuator servo - 1 : 1 interleave - Buffer memory parity - Read buffer look-ahead - Self-diagnostics on power-up - Automatic retry and data correction on read errors - In-line alternate sector assignment for high performance - Reassignment of new defective sectors without the need to reformat - Automatic actuator lock - Dedicated head landing zone - No preventative maintenance required - Two Field Replaceable Units (FRU's): Electronic and File Seek Time --------- +----------------------------------+--------+ | |0661-371| +----------------------------------+--------+ |Track-to-Track msec. typ. | 2 | +----------------------------------+--------+ |Average msec. typ. | 11.5 | | msec. max. | 25 | +----------------------------------+--------+ |Latency msec. avg. | 6.95 | +----------------------------------+--------+ SCSI Data Transfer Rate Specification ------------------------------------- The SCSI data transfer rate is dependent on the mode, either synchronous or asynchronous. When the file is configured for a synchronous data transfer rate of 4.0 MB/sec (instantaneous), the average SCSI data transfer rate is realized will be at least 3.8 MB/sec. The asynchronous data transfer rate is depentend on both the initiator and target delays to the assertion and negation of the SCSI REQ and ACK signals. It is also dependent on SCSI cable delays. The file will assert or negate the REQ signal within 175 nsec of the assertion or negation of the ACK signal. The SCSI data transfer rate specification only applies to the Data phase for logical block data for Read, Write, Write and Verify, etc. commands is not specified. SCSI Bus Electrical Characteristics ----------------------------------- The following are for the Western Digital WD33C93A SCSI Bus Interface Controller is used in this drive. +------+--------------------------+---+---+-----+---------------+ |Symbol|Input Characteristics |Min|Max|Units|Conditions | +------+--------------------------+---+---+-----+---------------+ |IIL |Input leakage | |10 | uA |VIN=0.4 to VCC | +------+--------------------------+---+---+-----+---------------+ |IOL1 |SCSI output leakage | |50 | uA |VOUT=0.5 to VCC| | |(inactive) | | | | | +------+--------------------------+---+---+-----+---------------+ |IOL2 |Output leakage (tri-state)| |10 | uA |VOUT=0.4 to VCC| +------+--------------------------+---+---+-----+---------------+ |VIH |Input high voltage |2.0| | V | | +------+--------------------------+---+---+-----+---------------+ |VIL |Input low voltage | |0.8| V | | +------+--------------------------+---+---+-----+---------------+ |VIHYS |Schmitt trigger input |0.2| | V | | | |hysterisis (all SCSI pins)| | | | | +------+--------------------------+---+---+-----+---------------+ |VOH |Output high voltage |2.4| | V |IO=-400uA | +------+--------------------------+---+---+-----+---------------+ |VOL1 |SCSI output low voltage | |0.5| V |IO=48.0mA | +------+--------------------------+---+---+-----+---------------+ |VOL2 |Output low voltage | |0.4| V |IO=4.0mA | | |(all others) | | | | | +------+--------------------------+---+---+-----+---------------+ |VCC |Supply current | |20 | mA |Ta=+25 dec C. | +------+--------------------------+---+---+-----+---------------+ NOTE Ta = 0 to 70 deg. C VCC = +5V 0.25V, GND = 0V Acoustics Levels ---------------- Upper Limit Sound Power Requirements (Bels) +---------+----------------------------------+-------------+ | |Octave Band Center Frequency (Hz) | A-weighted | +---------+----+----+----+----+----+----+----+-------------+ |Mode | 125| 250| 500| 1 k| 2 k| 4 k| 8 k|Max. Sum | +---------+----+----+----+----+----+----+----+-------------+ |Idling | 4.5| 3.5| 3.3| 3.5| 4.3| 4.3| 4.0| 4.75 | +---------+----+----+----+----+----+----+----+-------------+ |Operating| 4.5| 4.0| 3.6| 3.8| 4.6| 4.6| 4.3| 5.00 | +---------+----+----+----+----+----+----+----+-------------+ NOTE The operating mode is simulated by seeking at a rate between 12 and 15 seeks per second. ECC Implementation ------------------ Six bytes of ECC are provided for each data block. The code has been configured to guarantee accurate correction of any single burst error of 11 bits or less. Single burst errors of length 12-27 bits are guaranteed to be accurately detected as uncorrectable errors. Single burst errors of length 28-48 bits are always detected, however, it is possible that miscorrection may occur. The overall miscorrection probability for length 28-48 bit errors is approximately 1.5 E -8. Single burst errors that are more than 48 bits in length will be subject to the same miscorrection probabilities, and additionally, may not be detected by code. The misdetection probability for errors greater than 48 bits long is approximately 3.5 E -15. Head/Disk/Spindle Assembly -------------------------- The head and disk assembly (HDA) is assembled in a clean room environment and contains the disks and actuator assembly. Air is constantly circulated and filtered through a high-efficiency filter when the drive is operational. Venting of the HDA is accomplished via an absolute breather filter. The HDA is shock mounted to minimize transmission of vibration through the chassis. The spindle is driven directly by an in-hub, brushless DC drive motor. The motor is dynamically balanced to ensure a low level of vibration. Dynamic braking is used to quickly stop the spindle. Thermal Compensation -------------------- The file periodically compensates certain all heads to account for movements caused by thermal changes. The compensation process is initiated automatically by the file and may result in performance degradation while in progress. The compensation process is started every five minutes during the first hour after power is applied, and every twenty five minutes thereafter. The heads are compensated one at a time until all heads are done. It takes 140 msec to compensate one head; about 1.8 sec to compensate all heads. ********************************************************************** G E N E R A L ********************************************************************** IBM SCSI INSTALLATION SCSI Installation Guide Generic Installation requirements ------------------------- To install a drive inside your computer or in an external storage enclosure for SCSI devices, you must have: 1 The documentation that came with your computer or storage enclosure. 2 The documentation that came with your hard drive. 3 A small, flat blade screwdriver. 4 A SCSI controller, which is either built into the system board or on an adapter inside your computer. 5 An installation kit, if it is required for your computer. Contact your place of purchase if you are not sure. 6 If you are installing this into a PS/2 computer, you will also need the up-to-date backup copy of your reference diskette and diagnostic diskette. WARNING: Do not open the static-protective bag containing the drive until instructed to do so. Static electricity can damage the drive. Hardware and software considerations Operating system ---------------- The operating system and hardware are two of the factors that determine the number of drives a computer can support. The manuals for your computer and operating system can help you to determine the number and type of hard disk drives you can use. Power supply ------------ Two factors that determine the number of internal drives that a computer or SCSI storage enclosure can support are: 1 The available current of the power supply 2 The nominal operating current of each drive installed Most computer power supplies have output over-current protection. If the total allowed current is exceeded, the power supply shuts down. The computer must be turned off and turned on again. SCSI ID Each SCSI device connected to a SCSI adapter must be assigned a unique SCSI identification number (ID). The ID you assign to this device depends on the number of SCSI devices connected to the SCSI adapter and the SCSI IDs already assigned to those devices. Note: All IBM SCSI controllers support SCSI IDs 6 through 0. (ID 7 is used for the SCSI controller.) Some SCSI controllers support SCSI IDs 15 through 8. If your SCSI controller supports more than seven devices, then you can use SCSI IDs 15 through 8. If you are not sure if your SCSI controller supports more than seven devices, refer to the documentation that came with your SCSI controller for information. If you have an IBM PS/2 computer, you can view your SCSI ID settings by accessing the system programs. From the main menu, select Set configuration. The select Set and view SCSI configuration. Other computers might have utility programs that enable you to view the SCSI configuration, or you might have to physically inspect the installed SCSI devices to see how the IDs are set. For more information, refer to the documentation that came with your computer or SCSI controller. Handling precautions -------------------- 1 Turn off all attached devices first; then turn off the computer. 2 Unplug all the power cords from electrical outlets before starting installation. 3 Disconnect all power cables from your computer and attached devices before starting installation. 4 Limit your movement. Movement can cause static electricity to build up around you. 5 Handle the drive carefully and by the edges. 6 Do not touch any exposed printed circuitry. 7 Prevent other people from touching the components or the drive. 8 When you are installing the drive, touch the static-protective package containing the drive to a metal expansion-slot screw or other unpainted metal surface on the computer, for at least 2 seconds. (This drains static electricity from the package and your body.) 9 When possible, remove the drive and install it directly into the computer without setting it down. If this is not possible, place the drive, component side up, on the static-protective bag on a flat surface until the drive is installed. 10 Do not place the drive on the computer cover or on a metal table. Installing the drive -------------------- These instructions guide you as you install the drive inside your computer or storage enclosure. Step 1. Setting the jumpers and terminators Note: Be sure you have chosen the SCSI ID before continuing. If you did not yet choose the SCSI ID, go to "SCSI IDs" above, then return here. Follow these steps to set the SCSI ID to match your chosen SCSI ID. 1 Touch the static-protective bag containing the drive to a metal expansionslot cover on the computer. This drains any static electricity from the package and your body. 2 Remove the drive from the static-protective bag, holding the drive by the edges. Do not touch any exposed components on the drive. 3 Place the drive on the bag, on a flat surface. 4 When the Auto Start feature is enabled, the hard disk drive motor starts as soon as the computer is turned on. Locate the Auto Start jumper by referring to the documentation that came with your drive. If the Auto Start jumper is not in place, the hard disk is started by a command from the SCSI controller. For drives installed in IBM computers or storage enclosures ensure that this jumper is off. The hard disk drive is started in a staggered sequence. This reduces the start-up load on the power supply. For non-IBM computer, refer to the documentation that came with your computer for further information. 5 Set the SCSI ID that you selected. To remove a jumper, pull it straight off. To install a jumper, line up the two holes in the jumper with the appropriate two pins on the drive. Then push the jumper onto the pins until it is completely seated and covers both pins. 6 Store any jumpers you do not use in a safe place, in case you need to change the SCSI ID for this drive later. WARNING: If you have extra jumpers, do not store them on any of the extra pins on the connector. Storing them on a set of pins could damage the drive. Step 2. Connecting the terminator The location of the drive you are installing inside the computer or storage enclosure determines whether you need to connect a terminator or put a jumper on the Enable Active Termination pins. Read the information in the following table to determine if you must install the terminator. For more information about termination, refer to the documentation that came with your computer. Note: A SCSI chain of devices consists of multiple SCSI devices connected by a SCSI cable to a SCSI controller. If the hard disk drive is: Then: The last physical device on a SCSI chain of Install the terminator devices inside the computer. The last physical device on a SCSI chain of Install the terminator devices inside an external storage enclosure. Step 3. Enabling term power If your drive has a jumper for term power and your SCSI controller is suppling term power, (check with the manufacturer of your controller) then you do not need to enable the term power. The jumper should be off. For help in locating the term power jumper, refer to the documentation that came with your drive. Step 4. Installing the drive For the specific information on installing a hard disk drive, refer to the documentation that came with your computer. You will be required to mount the drive inside your computer, and connect signal and power cables to the hard drive. When installed in an enclosure, the drive is attached by cable to the external connector of a SCSI controller. The controller can be either on a SCSI adapter or built into the system board inside of your computer. Note: Be sure to use the correct screws provided with your drive. Using the wrong ones might cause damage to the drive. Step 5. Completing the installation procedure The installation of the drive is complete. Reinstall the cover on the computer or storage enclosure. Store these instructions and any extra parts in a safe place in case you change your configuration. After installing your hard disk drive, use the information that came with your computer to reconfigure your system. When you power on your system, turn on all attached devices first; then turn on the computer. If you have any problems at this point, turn off all attached devices; then, turn off the computer and check that: 1 The cables are installed correctly 2 No options or cables are loose 3 The SCSI ID is properly set 4 No two SCSI drives have the same SCSI ID 5 The terminators are properly installed Turn on all attached devices; then, turn on the computer. If you still have a problem, refer to the troubleshooting information in the documentation that came with your computer. Step 6. Update configuration Whenever you add or remove an option from your computer, you must update the configuration information. Your computer might have an automatic configuration program, or you might have to follow a specific procedure. For more information, refer to the documentation that came with your computer. Step 7. Preparing the drive for use Having successfully installed the hard disk drive, you need to prepare it for use. Depending on the operating system you are using, you might need to partition then format the hard disk. Refer to the documentation that came with your operating system for information on how to format your new drive. To make the drive just installed your primary drive, you might need to create a new system partition on the drive. For information on creating a new system partition, refer to the documentation that came with your operating system. Troubleshooting --------------- You might be able to solve a problem yourself. Before calling IBM, you might want to try some or all of the following troubleshooting procedures. 1 Remove and reattach all drive cables 2 Remove and reseat the drive 3 Place the drive in a different slot, if one is available 4 If your drive contains jumpers or switches, check that they are set as specified 5 Reread any software instructions; be sure software settings are correct 6 Inspect the drive for damage, such as bent pins 7 Check the computer manual for instructions about the installation of upgrades. Look for a section about system setup or system configuration. Follow all procedures. 8 After completing these steps, reassemble the computer and connect the power cord. If you are still having problems and want to call IBM technical support, have available as much of the following information as possible: 1 Drive model or P/N and description 2 Computer manufacturer and model 3 Exact wording of error message (if any) 4 Description of the problem 5 Hardware and software configuration information for your system If possible, be at your computer. Your technical support rep might want to walk you through the problem during the call.